  • Miniature Circuit Breaker S202MT-C2, C-Char., 10kA, 2A, 2P
  • Specifically designed for traction and railway applications
  • Classified with Exigence 3, suitable for all parts of the vehicle
  • Current limiting with delayed thermal tripping mechanism for overload protection
  • Electromechanic tripping mechanism for short circuit protection
  • Available in different characteristics (C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P)
  • Breaking capacities up to 10 kA at 230/400 V AC
  • Rated currents up to 63A
  • Complies with IEC/EN 60898-1 and IEC/EN 60947-2 standards
  • Compatible with all system pro M compact accessories

Read more

  • Bottom-fitting auxiliary contact S2C-Hxx allows for 50% space saving and group signal creation
 

Product

Manufacturer Material ID -
S202MT-C2
Net Weight -
0.25kg

Additional Product Information

Country of Origin -
DE
Minimum Order Quantity -
1
UNSPSC -
39121601

Technical Specification

Built-in depth -
69 Millimetre
Release characteristic -
C
Degree of protection (IP) -
IP20
Voltage type -
AC
Recess depth -
69 Millimetre
Rated current -
2 Ampere
Rated voltage -
400 Volt
Frequency -
50 Hertz
Tripping characteristic (type/curve) -
C
Rated insulation voltage Ui -
440 Volt
Current limiting class -
3
Over voltage category -
3
Pollution degree -
3
Width in number of modular spacings -
2
Degree of protection (IP rating) -
IP20
Number of protected poles -
2
Connectable conductor cross section solid-core -
0.75 Square millimetre
Connectable conductor cross section multi-wired -
0.75 Square millimetre
Ambient temperature during operating -
-25 Degrees celsius
Additional equipment possible -
Number of poles (total) -
2
Rated short-circuit breaking capacity Icn EN 60898 at 400 V -
10 kiloampere
Rated short-circuit breaking capacity Icn EN 60898 at 230 V -
10 kiloampere
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V -
15 kiloampere
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V -
15 kiloampere
Rated impulse-withstand voltage (Uimp) -
4 Kilovolt