  • Modular, distributed I/O system with compact I/O modules in IP65/67.
  • Especially easy and flexible installation, even in extremely confined spaces.
  • Easy wiring
  • Easy commissioning
  • SIMATIC ET 200AL consists of the following components:
    • Interface module for communication with IO Controllers on PROFINET.
    • Interface module for communication with all masters on the PROFIBUS.
    • Bus adapters for connection to the ET 200SP I/O system.
    • Various I/O modules, 30 mm and 45 mm wide.
  • Maximum configuration of an ET 200AL station:
    • Up to 32 I/O modules with PROFINET or PROFIBUS in any combination
    • Up to 16 I/O modules at the ET 200SP in any combination
  • Connection of the modules via an internal backplane bus established using bus cables (ET connection).

Highlights

  • Compact dimensions
  • Low weight
  • Safety-oriented collective shutdown of the outputs (available soon)
  • High degree of user-friendliness due to the following design features:
    • Flexible mounting in all positions possible due to screw fastening through the front or side
    • Direct installation on even surfaces or aluminum mounting rails
    • Labels for the identification of channels, modules and slots
    • Integrated cable tie opening
    • Clear and CAx-compliant interface designations
    • Uniform coloring of the system interfaces and system cables
    • 1:1 assignment of channel status LED, I/O socket and label
    • Pin assignment on the side
  • I/O module portfolio comprising digital and analog modules as well as IO-Link communication module
  • Ambient temperature range from -25 °C to +55 °C
  • Extensive system functions
    • All interface and I/O modules support firmware update
    • Configuration control (option handling) via user software
    • System support of PROFIenergy for power saving purposes
    • Consistent use of identification and maintenance data IM0 to IM3/4 (electronic rating plate) for fast electronic and unambiguous identification of individual modules (Article No., serial number, etc.).

Benefits

Simple use:

  • Simple and flexible installation and wiring thanks to intelligent product design
  • Can be used in moving devices due to its low weight
  • Scalable station design using modules with different functionalities and number of channels
  • Shortening of commissioning times and plant downtimes due to diagnostics

Compact design:

  • Small dimensions of the I/O modules

Strong performance

  • Communication connection of sensors and actuators via IO-Link
  • Configuration control (option handling) via user software
  • Greater energy efficiency due to system-integrated PROFIenergy

Application

SIMATIC ET 200AL is a distributed I/O device with degree of protection IP65/67 and easy handling and installation.
Due to the high degree of protection and robustness, small dimensions and low weight, ET 200AL is especially suitable for use at the machine and on moving plant sections.

SIMATIC ET 200 permits the user to access digital and analog signals and IO-Link data via PROFIBUS or PROFINET at low cost.

Design

  • Variable and modular station configuration:
    Using a bus cable, the I/O modules are interconnected, or connected to the interface module or the ET 200SP I/O system via an internal backplane bus (ET connection). The modules can be installed up to 15 m apart from each other.
  • Compact dimensions for use in extremely confined spaces:
    the width of the interface module is 45 mm; the I/O modules are 30 mm or 45 mm wide.
  • Can be mounted directly in a machine or assembly line:
    screw fastening through the front or side in all mounting positions, both on even surfaces or on aluminum mounting rails using sliding blocks.
  • Maximum configuration:
    • PROFINET: max. 32 I/O modules with 1430 bytes of input/output data each.
    • PROFIBUS DP: max. 32 I/O modules with 244 bytes of input/output data each.
    • ET 200SP: max. 16 I/O modules.
  • Module wiring:
    The module is connected via the internal backplane bus (ET connection) by means of a bus cable and power is supplied via power supply cables, in both cases with the M8 connection system. Different types of pre-assembled cables in various lengths are available for this purpose. The identical coloring of the system interfaces and system cables and the meaningful interface designations permit quick and easy assignment during wiring.
  • Signal wiring:
    • I/O modules with M8 or M12 connection technology for the connection of digital signals.
    • I/O module with M12 connection technology for the connection of analog signals.
    • IO-Link Master with M12 connection (port type B) for the connection of IO-Link devices.
  • Integrated cable tie:
    due to the integrated cable tie opening in the modules, the cables can be bundled and supported direct at the module if required.
  • Labels:
    For the identification of channels, modules and slots; supplied with the modules. The labels can be mechanically inscribed using commercially available labeling systems.

Interface modules

The following interface modules are available:

  • IM1 57-1 PN, for connecting ET 200AL to PROFINET
  • IM1 57-1 DP, for connecting ET 200AL to PROFIBUS DP

The interface modules have two backplane outlets (ET connection 1 and 2) to which the I/O modules are connected.
The I/O modules are connected to the ET 200SP I/O system via a ET 200SP bus adapter.

I/O modules

The following I/O modules are available:

  • Digital input module DI 8X24VDC, 8XM8
  • Digital input module DI 8X24VDC, 4XM12
  • Digital input module DI 16X24VDC, 8XM12
  • Digital output module DQ 8X24VDC/2A, 8XM12
  • Digital input/digital output module DIQ 4+DQ 4X24VDC/0.5A, 8XM8
  • Digital input/digital output module DIQ 4+DQ 4X24VDC/0.5A, 4XM12
  • Digital input / output module DIQ 16X24VDC/0.5A, 8XM12
  • Analog input module AI 4XU/I/RTD, 4XM12
  • Analog output module AQ 4xU/I, 4xM12
  • IO-Link master CM 4X IO-LINK, 4XM12

Accessories

  • Bus cable M8 for ET connection (various designs and lengths)
  • M8 connector for ET connection for assembly by the customer
  • ET Connection fast stripping tool
  • Power cable M8 (various designs and lengths)
  • M8 power connector, for assembly by the customer
  • Labels

Function

Mode of operation

Via PROFINET, PROFIBUS or ET 200SP, a central controller can access the distributed I/O modules of the ET 200AL in the same way as central I/O modules.
Communication is carried out fully automatically between the I/O controller in the central controller and the IM 157-1 or IM 155. Interference-free internal data transfer using shielded cables.

Comprehensive, module-specific diagnostics with plain text messages enables rapid location and elimination of system faults in the shortest possible time. Annoying plant downtimes belong to the past, and availability is significantly increased.

Configuration, parameterization and diagnostics

The ET 200AL is configured and assigned parameters via TIA Portal, STEP 7 or the configuration tool of the controller used.

The IO-Link master is configured using the S7-PCT (Port Configuration Tool).

PLC's
PLC's
I/O systems for in cabinets
I/O systems for in cabinets
I/O systems for in the field
I/O systems for in the field
Software
Software
HMI
HMI
Industrial PC's
Industrial PC's
Industrial IoT Gateway
Industrial IoT Gateway
Automatic door controls
Automatic door controls

Did you know, we are an entrusted Siemens approved partner?

Loading...