Filter products

TIA Portal - WinCC

With SINAMICS Start Drive for intuitive integration of SINAMICS drives, the TIA Portal offers the engineering software for industrial automation.

TIA Portal - WinCC
TIA Portal - WinCC

Overview

Basic Panels (2nd Generation)

SIMATIC HMI Basic Panels (2nd Generation) with their fully developed HMI basic functions are the ideal entry-level series for simple HMI applications.

The device family offers panels with 4″, 7″, 9″ and 12″ displays, as well as combined key and touch operation.

The innovative high-resolution widescreen displays with 64 000 colors are also suitable for upright installation, and they can be dimmed down to 100%. The innovative operator interface with improved usability opens up a diverse range of options thanks to new controls and graphics. The new USB interface enables the connection of keyboard, mouse or barcode scanner, and supports the simple archiving of data on a USB flash drive as well as the manual backup and restoring of the complete panel.

The integrated Ethernet or RS 485/422 interface (version-specific) enables simple connection to the controller.

http://www.siemens.com/basic-panels

Benefits

  • Integral component of Totally Integrated Automation (TIA):
    Enhanced productivity, minimization of engineering costs, reduction of lifecycle costs

    • Can also be deployed in an upright position where installation space is restricted
    • Short configuring and commissioning times
    • Service-friendly thanks to maintenance-free design
  • Simple and user-friendly representation of process values thanks to, for example, input/output fields, vector graphics, trend curves, bar charts, text and bitmaps
  • Flexible connection of USB stick, keyboard, mouse or barcode scanner using USB port
  • Graphics library available with off-the-shelf picture objects
  • Can be used worldwide:
    • 32 languages can be configured (incl. Asian and Cyrillic character sets)
    • You can switch between up to 10 languages online
    • Language-dependent texts and graphics

Application

The SIMATIC HMI Basic Panels can be used wherever compact machines and plants are controlled and monitored locally, such as in production, process and building automation. They may be used in all kinds of industries and applications.

Design

The SIMATIC HMI Basic Panels are installation-compatible with the existing touch devices of the product family of Panels and Multi Panels.

KTP400 Basic

  • Dimmable 4.3″ widescreen TFT display with 64 000 colors
  • 1 Ethernet interface (TCP/IP, PROFINET)
  • 1 USB interface
  • Touch screen and 4 tactile function keys

KTP700 Basic

  • Dimmable 7″ widescreen TFT display with 64 000 colors
  • 1 Ethernet interface (TCP/IP, PROFINET) or 1 RS 485/422 interface (MPI, PROFIBUS DP; separate version)
  • 1 USB interface
  • Touch screen and 8 tactile function keys

KTP900 Basic

  • Dimmable 9″ widescreen TFT display with 64 000 colors
  • 1 Ethernet interface (TCP/IP, PROFINET)
  • 1 USB interface
  • Touch screen and 8 tactile function keys

KTP1200 Basic

  • Dimmable 12″ widescreen TFT display with 64 000 colors
  • 1 Ethernet interface (TCP/IP, PROFINET) or 1 RS 485/422 interface (MPI, PROFIBUS DP; separate version)
  • 1 USB interface
  • Touch screen and 10 tactile function keys

Function

  • Input/output fields
    for displaying and modifying process parameters
  • Buttons
    are used for direct triggering of functions and actions. Up to 16 functions can be configured simultaneously on buttons.
  • Graphics
    can be used as icons instead of text to “label” function keys or buttons. They can also be used as full-screen background images.
    The configuration tool contains a library with extensive graphics and diverse objects. All editors with an OLE interface (such as PaintShop, Designer or CorelDraw) can be used as graphics editors
  • Vector graphics
    Simple geometric basic forms (line, circle and rectangle) can be created direct in the configuring tool
  • Predefined
    for labeling function keys, process pictures and process values in different font sizes
  • Curve functions and bars
    are used for graphical display of dynamic values
  • Language selection:
    • 10 online languages, 32 configuration languages incl. Asian and Cyrillic character sets
    • Language-dependent texts and graphics
  • User administration (security) in accordance with the requirements of the different industries
    • Authentication with user ID and password
    • User-group-specific rights
  • Alarm logging
    • Discrete messages
    • Analog messages
    • Freely-definable message classes (e.g. status/fault messages) for definition of acknowledgment response and display of message events
    • Message history
  • Recipe management
  • Help texts
    for process screens, messages and variables
  • Browser control
    for easy access to the Web server of the S7 and LOGO!
  • Arithmetic functions
  • Limit value monitoring
    for reliable process control of inputs and outputs
  • Indicator light
    for indicating machine and plant statuses
  • Scheduler for global function execution in case of global events
  • Archiving of process values and alarms on USB stick in .txt format
  • USB port for simple connection of USB stick, keyboard, mouse or barcode scanner
  • Template concept for creation of screen templates (screen elements configured in the template appear in every screen)
  • Simple maintenance and configuration thanks to:
    • Backup/restore of configuring, operating system and firmware on/from a USB stick or PC using ProSave for fast commissioning and for simple replacement of devices
    • Configuration download via MPI/PROFIBUS DP or PROFINET
    • Automatic transfer identification
    • Individual brightness adjustment and calibration
    • Clean screen
    • Real time clock with battery backup (backup time typically 6 weeks)
    • No battery required

Configuration

The configuration is implemented using the engineering software SIMATIC WinCC Basic, Comfort, Professional or SIMATIC STEP 7 Basic/Professional (with integrated WinCC Basic).

Integration

The Basic Panels can be connected to:

  • SIMATIC S7 controllers
  • Non-Siemens controllers (applies for DP devices)
    • Allen Bradley DF1
    • Modicon Modbus RTU
    • Mitsubishi FX
    • Omron Hostlink/Multilink
  • Non-Siemens controllers (non-Siemens drivers for PN devices)
    • Allen Bradley Ethernet/IP
    • Modicon Modbus TCP/IP
    • Mitsubishi MC TCP/IP

Note:

For further information, see “System interfaces”.

Technical specifications

Article number 6AV2123-2DB03-0AX0 6AV2123-2GB03-0AX0 6AV2123-2GA03-0AX0
SIMATIC HMI KTP400 Basic SIMATIC HMI KTP700 Basic SIMATIC HMI KTP700 Basic DP
General information
Product type designation KTP400 Basic color PN KTP700 Basic color PN KTP700 Basic color DP
Display
Design of display TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting
Screen diagonal 4.3 in 7 in 7 in
Display width 95 mm 154.1 mm 154.1 mm
Display height 53.9 mm 85.9 mm 85.9 mm
Number of colors 65 536 65 536 65 536
Resolution (pixels)
● Horizontal image resolution 480 Pixel 800 Pixel 800 Pixel
● Vertical image resolution 272 Pixel 480 Pixel 480 Pixel
Backlighting
● MTBF backlighting (at 25 °C) 20 000 h 20 000 h 20 000 h
● Backlight dimmable Yes Yes Yes
Keyboard fonts
● Function keys
— Number of function keys 4 8 8
— Number of function keys with LEDs 0 0 0
● Keys with LED No No No
● System keys No No No
● Numeric keyboard Yes; Onscreen keyboard Yes; Onscreen keyboard Yes; Onscreen keyboard
● alphanumeric keyboard Yes; Onscreen keyboard Yes; Onscreen keyboard Yes; Onscreen keyboard
Touch operation
● Design as touch screen Yes Yes Yes
Installation type/mounting
Mounting position vertical vertical vertical
Mounting in portrait format possible Yes Yes Yes
Mounting in landscape format possible Yes Yes Yes
maximum permissible angle of inclination without external ventilation 35° 35° 35°
Supply voltage
Type of supply voltage DC DC DC
Rated value (DC) 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V
Input current
Current consumption (rated value) 125 mA 230 mA 230 mA
Starting current inrush I²t 0.2 A²·s 0.2 A²·s 0.2 A²·s
Power
Active power input, typ. 3 W 5.5 W 5.5 W
Processor
Processor type ARM ARM ARM
Memory
Flash Yes Yes Yes
RAM Yes Yes Yes
Memory available for user data 10 Mbyte 10 Mbyte 10 Mbyte
Type of output
Acoustics
● Buzzer Yes Yes Yes
● Speaker No No No
Time of day
Clock
● Hardware clock (real-time) Yes Yes Yes
● Software clock Yes Yes Yes
● retentive Yes; Back-up duration typically 6 weeks Yes; Back-up duration typically 6 weeks Yes; Back-up duration typically 6 weeks
● synchronizable Yes Yes Yes
Interfaces
Number of industrial Ethernet interfaces 1 1 0
Number of RS 485 interfaces 0 0 1
Number of RS 422 interfaces 0 0 1; together with RS 485
Number of RS 232 interfaces 0 0 0; with optional adapter
Number of USB interfaces 1; Up to 16 GB 1; Up to 16 GB 1; Up to 16 GB
Number of 20 mA interfaces (TTY) 0 0 0
Number of parallel interfaces 0 0 0
Number of other interfaces 0 0 0
Number of SD card slots 0 0 0
With software interfaces No No No
Industrial Ethernet
● Industrial Ethernet status LED 2 2 0
Protocols
PROFINET Yes Yes No
Supports protocol for PROFINET IO No No No
IRT No No No
PROFIBUS No No Yes
MPI No No Yes
Protocols (Ethernet)
● TCP/IP Yes Yes No
● DHCP Yes Yes No
● SNMP Yes Yes No
● DCP Yes Yes No
● LLDP Yes Yes No
WEB characteristics
● HTTP No No No
● HTML No No No
Redundancy mode
● MRP No No No
Further protocols
● CAN No No No
● EtherNet/IP Yes Yes No
● MODBUS Yes; Modicon (MODBUS TCP/IP) Yes; Modicon (MODBUS TCP/IP) Yes; Modicon (MODBUS RTU)
Interrupts/diagnostics/status information
Diagnostic messages
● Diagnostic information readable No No No
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes Yes Yes
● Limit class B, for use in residential areas No No No
Degree and class of protection
IP (at the front) IP65 IP65 IP65
Enclosure Type 4 at the front Yes Yes Yes
Enclosure Type 4x at the front Yes Yes Yes
IP (rear) IP20 IP20 IP20
Standards, approvals, certificates
CE mark Yes Yes Yes
cULus Yes Yes Yes
RCM (formerly C-TICK) Yes Yes Yes
KC approval Yes Yes Yes
Use in hazardous areas
● ATEX Zone 2 No No No
● ATEX Zone 22 No No No
● IECEx Zone 2 No No No
● IECEx Zone 22 No No No
● cULus Class I Zone 1 No No No
● cULus Class I Zone 2, Division 2 No No No
● FM Class I Division 2 No No No
Marine approval
● Germanischer Lloyd (GL) Yes Yes Yes
● American Bureau of Shipping (ABS) Yes Yes Yes
● Bureau Veritas (BV) Yes Yes Yes
● Det Norske Veritas (DNV) Yes Yes Yes
● Lloyds Register of Shipping (LRS) Yes Yes Yes
● Nippon Kaiji Kyokai (Class NK) Yes Yes Yes
● Polski Rejestr Statkow (PRS) No No No
● Chinese Classification Society (CCS) No No No
Ambient conditions
Suited for indoor use Yes Yes
Suited for outdoor use No No
Ambient temperature during operation
● Operation (vertical installation)
— For vertical installation, min. 0 °C 0 °C 0 °C
— For vertical installation, max. 50 °C 50 °C 50 °C
● Operation (max. tilt angle)
— At maximum tilt angle, min. 0 °C 0 °C 0 °C
— At maximum tilt angle, min. 40 °C 40 °C 40 °C
● Operation (vertical installation, portrait format)
— For vertical installation, min. 0 °C 0 °C 0 °C
— For vertical installation, max. 40 °C 40 °C 40 °C
● Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min. 0 °C 0 °C 0 °C
— At maximum tilt angle, min. 35 °C 35 °C 35 °C
Ambient temperature during storage/transportation
● min. -20 °C -20 °C -20 °C
● max. 60 °C 60 °C 60 °C
Relative humidity
● Operation, max. 90 %; no condensation 90 %; no condensation 90 %; no condensation
Operating systems
proprietary Yes Yes Yes
pre-installed operating system
● Windows CE No No No
Configuration
Message indicator Yes Yes Yes
Alarm system (incl. buffer and acknowledgment) Yes Yes Yes
Process value display (output) Yes Yes Yes
Process value default (input) possible Yes Yes Yes
Recipe management Yes Yes Yes
Configuration software
● STEP 7 Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal)
● STEP 7 Professional (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal)
● WinCC flexible Compact No No No
● WinCC flexible Standard No No No
● WinCC flexible Advanced No No No
● WinCC Basic (TIA Portal) Yes Yes Yes
● WinCC Comfort (TIA Portal) Yes Yes Yes
● WinCC Advanced (TIA Portal) Yes Yes Yes
● WinCC Professional (TIA Portal) Yes Yes Yes
Languages
Online languages
● Number of online/runtime languages 10 10 10
Project languages
● Languages per project 32 32 32
Functionality under WinCC (TIA Portal)
Libraries Yes Yes Yes
Applications/options
● Web browser Yes Yes No
● SIMATIC WinCC Sm@rtServer Yes; Available with WinCC (TIA Portal) V14 or higher Yes; Available with WinCC (TIA Portal) V14 or higher No
Number of Visual Basic Scripts No No No
Task planner Yes Yes Yes
● time-controlled No No No
● task-controlled Yes Yes Yes
Help system Yes Yes Yes
● Number of characters per info text 500 500 500
Message system
● Number of alarm classes 32 32 32
● Bit messages
— Number of bit messages 1 000 1 000 1 000
● Analog messages
— Number of analog messages 25 25 25
● S7 alarm number procedure No No No
● System messages HMI Yes Yes Yes
● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
● Number of characters per message 80 80 80
● Number of process values per message 8 8 8
● Acknowledgment groups Yes Yes Yes
● Message indicator Yes Yes Yes
● Message buffer
— Number of entries 256 256 256
— Circulating buffer Yes Yes Yes
— retentive Yes Yes Yes
— maintenance-free Yes Yes Yes
Recipe management
● Number of recipes 50 50 50
● Data records per recipe 100 100 100
● Entries per data record 100 100 100
● Size of internal recipe memory 256 kbyte 256 kbyte 256 kbyte
● Recipe memory expandable No No No
Variables
● Number of variables per device 800 800 800
● Number of variables per screen 100 100 100
● Limit values Yes Yes Yes
● Multiplexing Yes Yes Yes
● Structures No No No
● Arrays Yes Yes Yes
Images
● Number of configurable images 250 250 250
● Permanent window/default Yes Yes Yes
● Global image Yes Yes Yes
● Pop-up images No No No
● Slide-in images No No No
● Image selection by PLC Yes Yes Yes
● Image number in the PLC Yes Yes Yes
Image objects
● Number of objects per image 100 100 100
● Text fields Yes Yes Yes
● I/O fields Yes Yes Yes
● Graphic I/O fields (graphics list) Yes Yes Yes
● Symbolic I/O fields (text list) Yes Yes Yes
● Date/time fields Yes Yes Yes
● Switches Yes Yes Yes
● Buttons Yes Yes Yes
● Graphic display Yes Yes Yes
● Icons Yes Yes Yes
● Geometric objects Yes Yes Yes
Complex image objects
● Number of complex objects per screen 10 10 10
● Alarm view Yes Yes Yes
● Trend view Yes Yes Yes
● User view Yes Yes Yes
● Status/control No No No
● Sm@rtClient view No No No
● Recipe view Yes Yes Yes
● f(x) trend view No No No
● System diagnostics view Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
● Media Player No No No
● HTML browser Yes Yes No
● PDF display No No No
● IP camera display No No No
● Bar graphs Yes Yes Yes
● Sliders No No No
● Pointer instruments No No No
● Analog/digital clock No No No
Lists
● Number of text lists per project 300 300 300
● Number of entries per text list 100 100 100
● Number of graphics lists per project 100 100 100
● Number of entries per graphics list 100 100 100
Archiving
● Number of archives per device 2; One message and one process value archive 2; One message and one process value archive 2; One message and one process value archive
● Number of entries per archive 10 000 10 000 10 000
● Message archive Yes Yes Yes
● Process value archive Yes Yes Yes
● Archiving methods
— Sequential archive Yes Yes Yes
— Short-term archive Yes Yes Yes
● Memory location
— Memory card No No No
— USB memory Yes Yes Yes
— Ethernet No No No
● Data storage format
— CSV No No No
— TXT Yes Yes Yes
— RDB No No No
Security
● Number of user groups 50 50 50
● Number of user rights 32 32 32
● Number of users 50 50 50
● Password export/import Yes Yes Yes
● SIMATIC Logon No No No
Character sets
● Keyboard fonts
— US English Yes Yes Yes
Transfer (upload/download)
● MPI/PROFIBUS DP No No Yes
● USB No No No
● Ethernet Yes Yes No
● using external storage medium Yes Yes Yes
Process coupling
● S7-1200 Yes Yes Yes
● S7-1500 Yes Yes Yes
● S7-200 Yes Yes Yes
● S7-300/400 Yes Yes Yes
● LOGO! Yes Yes Yes
● WinAC Yes Yes Yes
● SINUMERIK Yes; No access to NCK data Yes; No access to NCK data Yes; No access to NCK data
● SIMOTION Yes Yes Yes
● Allen Bradley (EtherNet/IP) Yes Yes No
● Allen Bradley (DF1) No No Yes
● Mitsubishi (MC TCP/IP) Yes Yes No
● Mitsubishi (FX) No No Yes
● OMRON (FINS TCP) No No No
● OMRON (LINK/Multilink) No No Yes
● Modicon (Modbus TCP/IP) Yes Yes No
● Modicon (Modbus) No No Yes
Service tools/configuration aids
● Backup/Restore manually Yes Yes Yes
● Backup/Restore automatically No No No
● Simulation Yes Yes Yes
● Device switchover Yes Yes Yes
Peripherals/Options
Peripherals
● Printer No No No
● SIMATIC HMI MM memory card: Multi Media Card No No No
● SIMATIC HMI SD memory card: Secure Digital memory card No No No
● SIMATIC HMI CF memory card Compact Flash Card No No No
● USB memory Yes Yes Yes
● SIMATIC IPC USB Flashdrive (USB stick) Yes Yes Yes
● SIMATIC HMI USB stick Yes Yes Yes
Mechanics/material
Enclosure material (front)
● Plastic Yes Yes Yes
● Aluminum No No No
● Stainless steel No No No
Dimensions
Width of the housing front 141 mm 214 mm 214 mm
Height of housing front 116 mm 158 mm 158 mm
Mounting cutout, width 123 mm 197 mm 197 mm
Mounting cutout, height 99 mm 141 mm 141 mm
Overall depth 33 mm 39 mm 39 mm
Weights
Weight without packaging 360 g 780 g 800 g
Weight incl. packaging 470 g 990 g 1 kg

Article number 6AV2123-2JB03-0AX0 6AV2123-2MB03-0AX0 6AV2123-2MA03-0AX0
SIMATIC HMI KTP900 Basic SIMATIC HMI KTP1200 Basic SIMATIC HMI KTP1200 Basic DP
General information
Product type designation KTP900 Basic color PN KTP1200 Basic color PN KTP1200 Basic color DP
Display
Design of display TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting
Screen diagonal 9 in 12 in 12 in
Display width 198 mm 261.1 mm 261.1 mm
Display height 111.7 mm 163.2 mm 163.2 mm
Number of colors 65 536 65 536 65 536
Resolution (pixels)
● Horizontal image resolution 800 Pixel 1 280 Pixel 1 280 Pixel
● Vertical image resolution 480 Pixel 800 Pixel 800 Pixel
Backlighting
● MTBF backlighting (at 25 °C) 20 000 h 20 000 h 20 000 h
● Backlight dimmable Yes Yes Yes
Keyboard fonts
● Function keys
— Number of function keys 8 10 10
— Number of function keys with LEDs 0 0 0
● Keys with LED No No No
● System keys No No No
● Numeric keyboard Yes; Onscreen keyboard Yes; Onscreen keyboard Yes; Onscreen keyboard
● alphanumeric keyboard Yes; Onscreen keyboard Yes; Onscreen keyboard Yes; Onscreen keyboard
Touch operation
● Design as touch screen Yes Yes Yes
Installation type/mounting
Mounting position vertical vertical vertical
Mounting in portrait format possible Yes Yes Yes
Mounting in landscape format possible Yes Yes Yes
maximum permissible angle of inclination without external ventilation 35° 35° 35°
Supply voltage
Type of supply voltage DC DC DC
Rated value (DC) 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V
Input current
Current consumption (rated value) 230 mA 510 mA 550 mA
Starting current inrush I²t 0.2 A²·s 0.2 A²·s 0.2 A²·s
Power
Active power input, typ. 5.5 W 12.2 W 13.2 W
Processor
Processor type ARM ARM ARM
Memory
Flash Yes Yes Yes
RAM Yes Yes Yes
Memory available for user data 10 Mbyte 10 Mbyte 10 Mbyte
Type of output
Acoustics
● Buzzer Yes Yes Yes
● Speaker No No No
Time of day
Clock
● Hardware clock (real-time) Yes Yes Yes
● Software clock Yes Yes Yes
● retentive Yes; Back-up duration typically 6 weeks Yes; Back-up duration typically 6 weeks Yes; Back-up duration typically 6 weeks
● synchronizable Yes Yes Yes
Interfaces
Number of industrial Ethernet interfaces 1 1 0
Number of RS 485 interfaces 0 0 1
Number of RS 422 interfaces 0 0 1; together with RS 485
Number of RS 232 interfaces 0 0 0; with optional adapter
Number of USB interfaces 1; Up to 16 GB 1; Up to 16 GB 1; Up to 16 GB
Number of 20 mA interfaces (TTY) 0 0 0
Number of parallel interfaces 0 0 0
Number of other interfaces 0 0 0
Number of SD card slots 0 0 0
With software interfaces No No No
Industrial Ethernet
● Industrial Ethernet status LED 2 2 0
Protocols
PROFINET Yes Yes No
Supports protocol for PROFINET IO No No No
IRT No No No
PROFIBUS No No Yes
MPI No No Yes
Protocols (Ethernet)
● TCP/IP Yes Yes No
● DHCP Yes Yes No
● SNMP Yes Yes No
● DCP Yes Yes No
● LLDP Yes Yes No
WEB characteristics
● HTTP No No No
● HTML No No No
Redundancy mode
● MRP No No No
Further protocols
● CAN No No No
● EtherNet/IP Yes Yes No
● MODBUS Yes; Modicon (MODBUS TCP/IP) Yes; Modicon (MODBUS TCP/IP) Yes; Modicon (MODBUS RTU)
Interrupts/diagnostics/status information
Diagnostic messages
● Diagnostic information readable No No No
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes Yes Yes
● Limit class B, for use in residential areas No No No
Degree and class of protection
IP (at the front) IP65 IP65 IP65
Enclosure Type 4 at the front Yes Yes Yes
Enclosure Type 4x at the front Yes Yes Yes
IP (rear) IP20 IP20 IP20
Standards, approvals, certificates
CE mark Yes Yes Yes
cULus Yes Yes Yes
RCM (formerly C-TICK) Yes Yes Yes
KC approval Yes Yes Yes
Use in hazardous areas
● ATEX Zone 2 No No No
● ATEX Zone 22 No No No
● IECEx Zone 2 No No No
● IECEx Zone 22 No No No
● cULus Class I Zone 1 No No No
● cULus Class I Zone 2, Division 2 No No No
● FM Class I Division 2 No No No
Marine approval
● Germanischer Lloyd (GL) Yes Yes Yes
● American Bureau of Shipping (ABS) Yes Yes Yes
● Bureau Veritas (BV) Yes Yes Yes
● Det Norske Veritas (DNV) Yes Yes Yes
● Lloyds Register of Shipping (LRS) Yes Yes Yes
● Nippon Kaiji Kyokai (Class NK) Yes Yes Yes
● Polski Rejestr Statkow (PRS) No No No
● Chinese Classification Society (CCS) No No No
Ambient conditions
Suited for indoor use Yes
Suited for outdoor use No
Ambient temperature during operation
● Operation (vertical installation)
— For vertical installation, min. 0 °C 0 °C 0 °C
— For vertical installation, max. 50 °C 50 °C 50 °C
● Operation (max. tilt angle)
— At maximum tilt angle, min. 0 °C 0 °C 0 °C
— At maximum tilt angle, min. 40 °C 40 °C 40 °C
● Operation (vertical installation, portrait format)
— For vertical installation, min. 0 °C 0 °C 0 °C
— For vertical installation, max. 40 °C 40 °C 40 °C
● Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min. 0 °C 0 °C 0 °C
— At maximum tilt angle, min. 35 °C 35 °C 35 °C
Ambient temperature during storage/transportation
● min. -20 °C -20 °C -20 °C
● max. 60 °C 60 °C 60 °C
Relative humidity
● Operation, max. 90 %; no condensation 90 %; no condensation 90 %; no condensation
Operating systems
proprietary Yes Yes Yes
pre-installed operating system
● Windows CE No No No
Configuration
Message indicator Yes Yes Yes
Alarm system (incl. buffer and acknowledgment) Yes Yes Yes
Process value display (output) Yes Yes Yes
Process value default (input) possible Yes Yes Yes
Recipe management Yes Yes Yes
Configuration software
● STEP 7 Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal)
● STEP 7 Professional (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal)
● WinCC flexible Compact No No No
● WinCC flexible Standard No No No
● WinCC flexible Advanced No No No
● WinCC Basic (TIA Portal) Yes Yes Yes
● WinCC Comfort (TIA Portal) Yes Yes Yes
● WinCC Advanced (TIA Portal) Yes Yes Yes
● WinCC Professional (TIA Portal) Yes Yes Yes
Languages
Online languages
● Number of online/runtime languages 10 10 10
Project languages
● Languages per project 32 32 32
Functionality under WinCC (TIA Portal)
Libraries Yes Yes Yes
Applications/options
● Web browser Yes Yes No
● SIMATIC WinCC Sm@rtServer Yes; Available with WinCC (TIA Portal) V14 or higher Yes; Available with WinCC (TIA Portal) V14 or higher No
Number of Visual Basic Scripts No No No
Task planner Yes Yes Yes
● time-controlled No No No
● task-controlled Yes Yes Yes
Help system Yes Yes Yes
● Number of characters per info text 500 500 500
Message system
● Number of alarm classes 32 32 32
● Bit messages
— Number of bit messages 1 000 1 000 1 000
● Analog messages
— Number of analog messages 25 25 25
● S7 alarm number procedure No No No
● System messages HMI Yes Yes Yes
● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
● Number of characters per message 80 80 80
● Number of process values per message 8 8 8
● Acknowledgment groups Yes Yes Yes
● Message indicator Yes Yes Yes
● Message buffer
— Number of entries 256 256 256
— Circulating buffer Yes Yes Yes
— retentive Yes Yes Yes
— maintenance-free Yes Yes Yes
Recipe management
● Number of recipes 50 50 50
● Data records per recipe 100 100 100
● Entries per data record 100 100 100
● Size of internal recipe memory 256 kbyte 256 kbyte 256 kbyte
● Recipe memory expandable No No No
Variables
● Number of variables per device 800 800 800
● Number of variables per screen 100 100 100
● Limit values Yes Yes Yes
● Multiplexing Yes Yes Yes
● Structures No No No
● Arrays Yes Yes Yes
Images
● Number of configurable images 250 250 250
● Permanent window/default Yes Yes Yes
● Global image Yes Yes Yes
● Pop-up images No No No
● Slide-in images No No No
● Image selection by PLC Yes Yes Yes
● Image number in the PLC Yes Yes Yes
Image objects
● Number of objects per image 100 100 100
● Text fields Yes Yes Yes
● I/O fields Yes Yes Yes
● Graphic I/O fields (graphics list) Yes Yes Yes
● Symbolic I/O fields (text list) Yes Yes Yes
● Date/time fields Yes Yes Yes
● Switches Yes Yes Yes
● Buttons Yes Yes Yes
● Graphic display Yes Yes Yes
● Icons Yes Yes Yes
● Geometric objects Yes Yes Yes
Complex image objects
● Number of complex objects per screen 10 10 10
● Alarm view Yes Yes Yes
● Trend view Yes Yes Yes
● User view Yes Yes Yes
● Status/control No No No
● Sm@rtClient view No No No
● Recipe view Yes Yes Yes
● f(x) trend view No No No
● System diagnostics view Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
● Media Player No No No
● HTML browser Yes Yes No
● PDF display No No No
● IP camera display No No No
● Bar graphs Yes Yes Yes
● Sliders No No No
● Pointer instruments No No No
● Analog/digital clock No No No
Lists
● Number of text lists per project 300 300 300
● Number of entries per text list 100 100 100
● Number of graphics lists per project 100 100 100
● Number of entries per graphics list 100 100 100
Archiving
● Number of archives per device 2; One message and one process value archive 2; One message and one process value archive 2; One message and one process value archive
● Number of entries per archive 10 000 10 000 10 000
● Message archive Yes Yes Yes
● Process value archive Yes Yes Yes
● Archiving methods
— Sequential archive Yes Yes Yes
— Short-term archive Yes Yes Yes
● Memory location
— Memory card No No No
— USB memory Yes Yes Yes
— Ethernet No No No
● Data storage format
— CSV No No No
— TXT Yes Yes Yes
— RDB No No No
Security
● Number of user groups 50 50 50
● Number of user rights 32 32 32
● Number of users 50 50 50
● Password export/import Yes Yes Yes
● SIMATIC Logon No No No
Character sets
● Keyboard fonts
— US English Yes Yes Yes
Transfer (upload/download)
● MPI/PROFIBUS DP No No Yes
● USB No No No
● Ethernet Yes Yes No
● using external storage medium Yes Yes Yes
Process coupling
● S7-1200 Yes Yes Yes
● S7-1500 Yes Yes Yes
● S7-200 Yes Yes Yes
● S7-300/400 Yes Yes Yes
● LOGO! Yes Yes Yes
● WinAC Yes Yes Yes
● SINUMERIK Yes; No access to NCK data Yes; No access to NCK data Yes; No access to NCK data
● SIMOTION Yes Yes Yes
● Allen Bradley (EtherNet/IP) Yes Yes No
● Allen Bradley (DF1) No No Yes
● Mitsubishi (MC TCP/IP) Yes Yes No
● Mitsubishi (FX) No No Yes
● OMRON (FINS TCP) No No No
● OMRON (LINK/Multilink) No No Yes
● Modicon (Modbus TCP/IP) Yes Yes No
● Modicon (Modbus) No No Yes
Service tools/configuration aids
● Backup/Restore manually Yes Yes Yes
● Backup/Restore automatically No No No
● Simulation Yes Yes Yes
● Device switchover Yes Yes Yes
Peripherals/Options
Peripherals
● Printer No No No
● SIMATIC HMI MM memory card: Multi Media Card No No No
● SIMATIC HMI SD memory card: Secure Digital memory card No No No
● SIMATIC HMI CF memory card Compact Flash Card No No No
● USB memory Yes Yes Yes
● SIMATIC IPC USB Flashdrive (USB stick) Yes Yes Yes
● SIMATIC HMI USB stick Yes Yes Yes
Mechanics/material
Enclosure material (front)
● Plastic Yes Yes Yes
● Aluminum No No No
● Stainless steel No No No
Dimensions
Width of the housing front 267 mm 330 mm 330 mm
Height of housing front 182 mm 245 mm 245 mm
Mounting cutout, width 251 mm 310 mm 310 mm
Mounting cutout, height 166 mm 221 mm 221 mm
Overall depth 55 mm 60 mm 60 mm
Weights
Weight without packaging 1 130 g 1 710 g 1 710 g
Weight incl. packaging 1 393 g 2.2 kg 2.2 kg

Dimensional drawings

All dimensions in mm. For installation cutout, see technical specifications.

KTP400 Basic, Basic Panel 2nd generation

KTP700 Basic, Basic Panel 2nd Generation

KTP700 Basic DP, Basic Panel 2nd Generation

KTP900 Basic, Basic Panel 2nd Generation

KTP1200 Basic, Basic Panel 2nd Generation

KTP1200 Basic DP, Basic Panel 2nd Generation