Search Products
Products
-
Automation
-
Industrial Communication
- Identification
-
Variable Speed Drives
-
LV Controlgear
Current Transformers Moulded Case Current Transformers
Three Phase Current Transformers
Split-Core Current Transformers
-
Switchgear and Circuit Protection
-
Power Supplies & Transformers
-
Safety
-
Process Instrumentation
Pressure Transmitters Analogue/HART
PROFIBUS PA
Pressure Switches Mechanical Pressure Switch
Diaphragm Seals Manifolds Pressure Transmitters Basic Pressure Transmitters
High Accuracy Pressure Transmitter
High Accuracy Hygienic Pressure Transmitter
Diaphragm Seals Manifolds Coriolis (Mass Flow) Transmitters
Low Flow Sensor
Medium Flow Sensor
Digital Coriolis Flow Meter
Modbus Digital Coriolis Flow Meter
Vortex Orifice Plates Pitot Tubes Averaging Pitot Tubes
GE Druck Multifunction
Loop
Electrical
RTD
Thermocouple
Liquid Bath
Temperature Blocks
Pressure
Frequency
-
Terminals & Connection System
-
Enclosures
- Climate Control
-
Sensors
-
Vision & Lighting
Locking - Power To Lock
Overview
AZM range solenoid interlocks, operating in combination with control elements of a machine, e.g. fail-safe standstill monitors or fail-safe delay timers, ensure that sliding, hinged and removable guarding devices, such as grids, hoods or doors, cannot be opened until hazardous conditions (e.g. running-down movements) have come to an end.
These solenoid interlocks are also used for cases in which the opening of a guarding device represents a non-permissible intrusion in a production process.
Design and mode of operation:
On the AZM range solenoid interlocks, the switching element with interlock is not physically connected to the actuator but functionally brought together or seperated on switching. When the guard device is opened in the uninterlocked condition, the actuator is seperated from the base unit. In the process, NC contacts are positively opened and NO contacts closed.
Interlocking is carried out by means of a blocking bolt / latching bolt. This latching bolt blocks the actuator so that it cannot be withdrawn from the interlock. The machine control circuit is only enabled when the actuator has been fed into the interlock and the latching bolt is in the blocking position. This is ensured by contact monitoring of the latching bolt.
There are two modes of interlocking. In the case of "Power to unlock", the latching bolt is held in the interlock by spring pressure. When the de-interlocking coil is energised, the interlock is removed and the NC contacts opened. The guarding device can be opened. For "Power to lock 1)", the mode of operation is reversed.
The AZM 161, 170, 190 and 415 solenoid interlocks are fitted with protection against incorrect locking. Depending on the type of unit, an individual coding of the actuator are possible.
The solenoid interlocks can be fitted in any desired mounting position. Protection class of the solenoid interlocks is IP 54, IP 65 or IP 67.
1) In accordance with the policy of the German Technical Assessors, these interlock may only be used after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply.
Cable Entry - M20
Cage Clamp
Screw Terminals
Separate Actuator
2 N/C and 2 N/C
1 N/O 1N/C and 1 N/O 1 N/C