  • PC-based operator control and monitoring system for visualizing and operating processes, production flows, machines and plants in all sectors – from the simple single-user station through to distributed multi-user systems with redundant servers and cross-location solutions with web clients. WinCC is the information hub for corporation-wide vertical integration.
  • The basic system configuration (WinCC basic software) includes industry-standard functions for signaling and acknowledging events, archiving of messages and measured values, logging of all process and configuration data, user administration and visualization.
  • The WinCC basic software forms the core of a wide range of different applications. Based on the open programming interfaces, a wide range of WinCC options (from Siemens Industry Automation) and WinCC add-ons have been developed (by Siemens-internal and external partners).
  • WinCC can be operated with every PC that meets the given HW requirements. The SIMATIC IPC product range is available in particular for the industrial use of WinCC systems. SIMATIC IPCs impress with their powerful PC technology, are designed for round-the-clock operation, and can be operated in both office areas and harsh industrial environments.

Current versions:

SIMATIC WinCC V7.5

Runs on:

  • Windows 10 Professional, Enterprise (64-bit)
  • Windows 10 Enterprise LTSB (64-bit)
  • Windows 2012 Server R2 (64-bit)
  • Windows 2016 Server (64-bit)

For WebNavigator Clients and DataMonitor Clients, also:

  • Windows 7 SP1 Professional, Enterprise, Ultimate (32-/64-bit)
  • Windows 8.1 Professional, Enterprise (32-/64-bit)

Please check the Siemens Online Support compatibility list for details:

https://support.industry.siemens.com/kompatool/pages/main/index.jsf?

SIMATIC WinCC V7.4 SP1

Runs on:

  • Windows 7 Professional, Enterprise, Ultimate (32-/64-bit)
  • Windows 8.1 Professional, Enterprise (32-/64-bit)
  • Windows 10 Professional, Enterprise, 2015 LTSB, 2016 LTSB (64-bit)
  • Windows 2008 Server R2 SP1 (64-bit)
  • Windows 2012 Server R2 (64-bit)
  • Windows 2016 Server (64-bit)
  • Includes Microsoft SQL Server 2014 SP1 (32-bit)

Use in virtual environments – for more information see:

http://support.automation.siemens.com/WW/view/en/49370459

SIMATIC SCADA and SIMATIC IPCs

Perfect interaction for optimum productivity.

  • Price advantage as “Package” comprising hardware and software
  • System-tested solutions reduce testing overhead
  • Simple ordering and synchronized logistics

Only if ordered together with the SIMATIC IPC.

Benefits

  • All-purpose
    • Solutions for all sectors
    • Multi-language for worldwide usage
    • Can be integrated into all automation solutions
  • All operator control & monitoring functions on board
    • User administration
    • Operator control and monitoring
    • Reporting, acknowledging, and archiving of events
    • Collecting, consolidating and archiving measured values (including long-term backup)
    • Logging and documenting of process and configuration data
  • Can be configured simply and efficiently
    • Configuration wizards let the user focus on the essentials
    • In the picture by means of cross-reference lists and screen property displays
    • Configuration of multi-language applications
    • Configuring tool for configuring bulk data
  • Universally scalable
    • Expandable from single station to client-server configurations
    • Increased availability by means of redundant servers
    • Process visualization via the Web with the WinCC WebNavigator or WebUX
  • Open standards for simple integration
    • Efficient real-time database MS SQL Server
    • Open for application modules with ActiveX controls
    • Visual Basic for Applications for individual expansions
    • OPC for cross-vendor communication
  • Process visualization with Plant Intelligence
    • Integrated evaluation functions for the online analysis (statistical process control)
    • Production optimization with the help of diverse options
  • Expandable using options and add-ons
    • Options for scalable configurations
    • Options for increasing the availability
    • Options for IT & business integration
    • Options for SCADA expansions
    • Options for validation in accordance with FDA 21 CFR Part 11
    • Options for the use of telecontrol protocols
  • Part of Totally Integrated Automation
    • Direct access to the tag and message configuration of the SIMATIC control system
    • Integrated diagnostic functions for increasing productivity

New with V7.5

  • Extended functionality for object-oriented configuration
    • Import and use of structured data types from S7-1500 PLCs and OPC UA data sources
    • Use of structure data types as an interface to the faceplates
  • Extended functionality for the design of the runtime interface
    • Additional characteristics for dynamization of SVG graphics from the WinCC library including support for WebUX
    • Integration of the central color palette in the project design template including option for changeover during runtime
  • Communication
    • OPC UA client enhanced for Alarm & Condition
    • Possible to configure access rights for WinCC tags via the WinCC OPC server
    • WinCC Cloud Connect for sending WinCC data to cloud systems using the MQTT protocol
  • Graphics Designer
    • Easier configuration of multi-language texts and font settings for all text elements in graphics
    • New animation option for dynamization of object properties without script programming
  • Other innovations
    • WinCC WebUX: Auto-Login for operate mode, enhanced features for trend control dynamization and central color palette for alarm configuration
    • Reworked tag simulator with new options for system tags for monitoring communication channel and login performance values
    • Structuring of WinCC images (PDLs) in subfolders possible
    • Menu and toolbars can be configured via new editor in Config Studio

Application

SIMATIC WinCC is designed for visualization and operation of processes, production flows, machines and plants. With its powerful process interface, especially to the SIMATIC family, and the secure data archiving, WinCC enables highly available solutions for the process control.

The sector-neutral basic system enables universal usage in all automation applications. Sector-specific solutions can, for example, be implemented using WinCC options (e.g. FDA options for the pharmaceutical industry) and sector-specific add-ons (e.g. for the water industry).

Design

SIMATIC WinCC is available as a complete package and as a runtime package with 128, 512, 2 048, 8 192, 65 536, 102 400, 153 600, 262 144 PowerTags. PowerTags are data points that are connected to controllers or other data sources over a WinCC channel. Up to 32 alarms can be obtained from one data point. Moreover, internal tags without coupling are available for additional system performance. In addition WinCC also contains 512 archive tags. Additional archive licenses can be obtained for larger quantity structures.

Licenses for a multi-user configuration

The system software with the required number of PowerTags and additionally the option WinCC/Server must be installed on the WinCC server. In the basic configuration, one RT Client License is sufficient for the WinCC Clients 1). An RC Client License is required to configure on clients 1). Remote configuration is possible if WinCC Clients without their own project (Uni Client) are configured on the server project.

1) The SQL Server Express is installed for RT / RC Clients.

Function

The powerful configuration functions of SIMATIC WinCC contribute to a reduced engineering and training overhead and lead to a more flexible use of personnel and greater operational reliability.

Anyone familiar with Microsoft Windows can also operate the WinCC Explorer, the central switching point of WinCC. Even large quantities of data can be processed intuitively and efficiently with the WinCC Configuration Studio.

In combination with other SIMATIC components, the system is also equipped with auxiliary functions, such as process diagnostics and maintenance. All SIMATIC engineering tools work together in the configuration of the functions.

SIMATIC WinCC offers a complete basic functionality for process visualization and operation. To this end WinCC has a number of editors and interfaces that can be used to individually configure this functionality according to the respective application. Expansions of a WinCC station for control tasks are also possible with minimal engineering effort.

WinCC editors Task or configurable runtime functionality
WinCC Explorer Central project management for the quick access to all project data and central settings
WinCC Graphics Designer Graphics system for user-defined visualization and operation via pixel-graphic objects
WinCC Configuration Studio Alarm LoggingSignaling system for detecting and archiving events with display and control options based on DIN 19235; freely selectable message classes, message display and loggingWinCC Tag LoggingProcess archiving for the acquisition, compression and storage of measured values, e.g. presentation in trend and table format as well as further processingWinCC User AdministratorFor managing users and authorizations
WinCC Report Designer Reporting and logging system for time and event-controlled documentation of messages, operator inputs and current process data in the form of user reports or project documentation in an arbitrary layout
WinCC Global Script Processing functions with limitless functionality by means of the use of VBScript and ANSI-C

Interfaces

Task or configurable runtime functionality
Communication channels Communication with lower-level controls (SIMATIC protocols, PROFIBUS DP and OPC server included in scope of supply)
Standard interfaces Facilitate the open integration of other Windows applications via WinCC, WinCC-OLE-DB, ActiveX, OLE, OPC etc.
Programming interfaces For the individual access to data and functions of WinCC and for the integration in user programs with VBA, VB Script, C-API (ODK), C-Script (ANSI-C)

Integration

Integration in company-wide solutions (IT and business integration)

WinCC is based on Microsoft technology, which ensures openness and integration capability. ActiveX and .net controls facilitate technology-specific and industry-specific expansions. Cross-manufacturer communication is also possible since WinCC can be used as an OPC client and server in addition to accessing current process values and supporting standards such as OPC HDA (Historical Data Access), OPC Alarm & Events, OPC XML Data Access, and OPC UA.

Just as important: Visual Basic for Applications (VBA) is available for user-specific expansions in engineering, and Visual Basic Scripting (VBS) as an easy-to-learn, open, runtime language. If desired, professional application developers can also use ANSI-C. The Open Development Kit (ODK) simplifies access to the API programming interfaces.

WinCC integrates a powerful and scalable archiving feature using database technology This provides the user with a variety of options: from high-performance archiving of current process data, to long-term archiving with high data compression, through to a connection to the central information hub in the form of a company-wide Process Historian. Versatile clients and tools for evaluation, the open interfaces, and special options (Connectivity Pack, Connectivity Station, IndustrialDataBridge) provide the basis for effective IT and business integration.

WinCC offers various security mechanisms, such as encrypted communication, to ensure secure operation of the plant. If external networks are accessed, for example, suitable protective measures (incl. IT security measures, such as network segmentation) should still also be taken.

You can find more information on the topic of Industrial Security on the Internet at:

http://www.siemens.com/industrialsecurity

Integration in automation solutions

WinCC is an open process visualization system and provides the option to connect the most diverse control systems.

Approved communication software

Use communication software with the listed product versions. Corresponding SIMATIC NET upgrades are available for upgrading older versions.

Number of connectable controllers

For the number of controllers which can be connected via Industrial Ethernet CP 1613, the following applies to a message frame length of 512 bytes:

Type of connection Number of nodes
SIMATIC S5 Ethernet Layer 4 + TCP/IP Up to 60
SIMATIC S7 Protocol Suite Up to 64
SIMATIC 505 Ethernet Layer 4 + TCP/IP Up to 60
SIMATIC S7-1200/1500 Channel Up to 128

Via PROFIBUS, a maximum of 8 controllers can be connected with CP 5612, and a maximum of 44 controllers with CP 5613. Industrial Ethernet is recommended when 10 or more controllers are used.

Mixed operation with different controllers

With their multi-protocol stack, the CP 1613 and CP 5613 communication processors enable the parallel operation of two protocols, such as for the mixed operation of different controllers, via a single bus cable. WinCC supports the operation of two similar interface boards only in connection with the channels SIMATIC S5 Ethernet Layer 4 (2 x CP 1613), SIMATIC S7 Protocol Suite (2 x CP 1613, 2 x CP 5613) as well as PROFIBUS DP (4 x CP 5613; max. 122 slaves for each CP 5613). In addition to communication via Industrial Ethernet CP 1613 or PROFIBUS CP 5613, one CP 5612/5622 can be used in each case for communication with SIMATIC S7 via MPI.

Client-server communication

Communication between the clients and the server is via TCP/IP protocol. Setting up a separate PC LAN is recommended. For small projects with a correspondingly low incidence of message frames, SIMATIC NET Industrial Ethernet communication can be used for both process communication (WinCC/server ↔ PLC) and PC-PC communication (WinCC/client ↔ WinCC/server).

Channel DLL PROFIBUS DP

In accordance with the PROFIBUS standard, DP/slaves are always permanently assigned to a DP master; i.e. a second WinCC station (DP/master) cannot access the same controllers (DP/slaves). This means that redundant operation of two WinCC stations is not possible using the PROFIBUS DP connection.

Connection to controllers from other manufacturers:

If a native driver is not available, OPC or OPC UA is available for connection to third-party controllers.

Current notes and information about OPC servers from various suppliers can be found at:

http://www.opcfoundation.org

WinCC supports the standards:

  • OPC Data Access 2.05a
  • OPC Data Access 3.00
  • OPC UA 1.02
  • OPC UA HA 1.20
  • OPC UA Alarms and Conditions 1.20
  • OPC Historical Alarms and Events 1.10
  • OPC XML Data Access 1.01 (Connectivity Pack/ Connectivity Station)
  • OPC HDA 1.20 (Connectivity Pack/Connectivity Station)
  • OPC A&E 1.10 (Connectivity Pack/Connectivity Station)
  • OPC UA Client Data Access
  • OPC UA Server Data Access, HDA, Alarm & Condition (Connectivity Pack/Connectivity Station)

Connection overview

Protocol Description
SIMATIC S7
SIMATIC S7 Protocol Suite Channel DLL for S7 functions via MPI, PROFIBUS or Ethernet Layer 4 + TCP/IP
SIMATIC S5
SIMATIC S5 Ethernet Layer 4 Channel DLL for S5 Layer 4 communication + TCP/IP
SIMATIC S5 Programmer Port AS511 Channel DLL and driver for serial communication with S5 using AS511 protocol to programmers port
SIMATIC S5 Serial 3964R Channel DLL and driver for serial communication with S5 using RK512 protocol
SIMATIC S5 PROFIBUS-FDL Channel DLL for S5-FDL
SIMATIC 505
SIMATIC 505 Serial Channel DLL and driver for serial communication with 505 using NITP/TBP protocol to SIMATIC 535/545/555/565/575
SIMATIC 505 Ethernet Layer 4 Channel DLL for 505 Layer 4 communication
SIMATIC 505 TCP/IP Channel DLL for 505 TCP/IP communication
SIMATIC S7-1200, S7-1500
SIMATIC S7-1200, S7-1500 Channel Channel DLL for S7-1200 and S7-1500 communication
Third-party controllers 
Allen Bradley
Ethernet IP
Channel DLL and drivers for communication with Allen Bradley controllers via Ethernet TCP/IP using Ethernet IP protocol
Modbus TCP/IP Channel DLL and drivers for communication with Modicon controllers via Ethernet TCP/IP using Modbus TCP/IP protocol
Mitsubishi MC TCP/IP Channel DLL and drivers for communication with Mitsubishi controllers via Ethernet TCP/IP using Mitsubishi MC TCP/IP protocol
Cross-manufacturer
OPC client for DA, XML DA Channel DLL for OPC communication; WinCC can acquire data from OPC server applications
OPC server for DA, XML DA, A&C Channel DLL for OPC communication; WinCC can acquire data from OPC server applications
OPC server for DA, XML DA, A&E, HDA Server applications for OPC communication; WinCC provides process data to OPC clients
OPC UA server for DA, HDA, A&C Server applications for OPC UA communication
PROFIBUS DP Channel DLL for PROFIBUS DP
SIMOTION Channel DLL for SIMOTION

Application note:

Parallel usage of the OPC client channel allows, for example, connection to an SNMP OPC server for visualization of the data contained there. The SNMP OPC server enables monitoring of any network components (such as switches) that support the SNMP protocol. You can find more information under SIMATIC NET Communications Systems/SNMP OPC Server.

PG/PC communication components for SIMATIC (for WinCC V7.5)

Industrial Ethernet SIMATIC
S5
Ethernet
Layer 4
SIMATIC
S5
TCP/IP
SIMATIC
S7
Protocol
Suite
SIMATIC
505
Ethernet
Layer 4
SIMATIC
505
TCP/IP 1)
Article No.
WinCC – channel DLL
SIMATIC S5 Ethernet Layer 4
Channel DLL for S5 Layer 4 communication + TCP/IP
Included in the basic package
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions
Included in the basic package
SIMATIC 505 Ethernet Layer 4
Channel DLL for 505 Layer 4 communication
Included in the basic package
SIMATIC 505 TCP/IP 1)
Channel DLL for 505 TCP/IP communication
Included in the basic package
Communication components for extension of the OS/OP
CP 1612 A2
PCI card for connecting a PG/PC to Industrial Ethernet (SOFTNET-S7 or SOFTNET-S7 Lean communication software must be ordered separately)
6GK1161-2AA01
SOFTNET-IE S7
Communication software for
S7 functions (max. 64 connections)
Version 15 2)3)
6GK1704-1CW15-0AA0
SOFTNET-IE S7 Lean
Communication software for S7 functions (max. 8 connections)
Version 15 2)3)
6GK1704-1LW15-0AA0
CP 1623
PCI Express X1 card (32-bit) for connecting a PG/PC to Industrial Ethernet (S7-1613 communication software required)
6GK1162-3AA00
CP 1628
PCI Express X1 card (32-bit) for connecting a PG/PC to Industrial Ethernet (HARDNET-IE S7 / S7-1613 communication software required)
6GK1162-8AA00
HARDNET-IE S7 / S7-1613
Communication software for
S7 functions, OPC, PG/OP
communication
Version 15 2)3)
6GK1716-1CB15-0AA0

• System interface possible

1) Via any interface board with NDIS 3.0 interface; no separate communication software required

2) See ordering data for SIMATIC NET upgrade packages

3) SIMATIC NET version V15 is supplied together with WinCC V7.5

4) SOFTNET-S7 Lean included in scope of supply of WinCC V7.5

Communications components for PG/PC for SIMATIC (for WinCC V7.4 SP1)

Industrial Ethernet SIMATIC
S5
Ethernet
Layer 4
SIMATIC
S5
TCP/IP
SIMATIC
S7
Protocol
Suite
SIMATIC
505
Ethernet
Layer 4
SIMATIC
505
TCP/IP 1)
Article No.
WinCC – channel DLL
SIMATIC S5 Ethernet Layer 4
Channel DLL for S5 Layer 4 communication + TCP/IP
Included in the basic package
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions
Included in the basic package
SIMATIC 505 Ethernet Layer 4
Channel DLL for 505 Layer 4 communication
Included in the basic package
SIMATIC 505 TCP/IP 1)
Channel DLL for 505 TCP/IP communication
Included in the basic package
Communication components for extension of the OS/OP
CP 1612 A2
PCI card for connecting a PG/PC to Industrial Ethernet (SOFTNET-S7 or SOFTNET-S7 Lean communication software must be ordered separately)
6GK1161-2AA01
SOFTNET-IE S7
Communication software for
S7 functions (max. 64 connections)
6GK1704-1CW14-0AA0
Version 14 SP1 2)3)
For Windows 7 SP1 Prof./Ult. (32/64-bit)
Windows 8.1 PRO (64-bit)
Windows 10 Server 2008 R2 SP1
Server 2012 R2 (64-bit)
SOFTNET-IE S7 Lean
Communication software for S7 functions (max. 8 connections)
6GK1704-1LW14-0AA0
Version 14 SP1 2)3)
For Windows 7 SP1 Prof./Ult. (32/64-bit)
Windows 8.1 PRO (64-bit)
Windows 10 Server 2008 R2 SP1
Server 2012 R2 (64-bit)
CP 1623
PCI Express X1 card (32-bit) for connecting a PG/PC to Industrial Ethernet (S7-1613 communication software required)
6GK1162-3AA00
CP 1628
PCI Express X1 card (32-bit) for connecting a PG/PC to Industrial Ethernet (HARDNET-IE S7 / S7-1613 communication software required)
6GK1162-8AA00
HARDNET-IE S7 / S7-1613
communication software for
S7 functions, OPC, PG/OP
communication
6GK1716-1CB13-0AA0
Version 13 SP2 2)3)
for Windows 7 SP1 (32/64-bit), Windows 8.1 (32/64-bit), Windows 2008 R2 SP1 Server, Server 2012 R2 (64-bit), and Windows 10 (64-bit)

• System interface possible

1) Via any interface board with NDIS 3.0 interface; no separate communication software required

2) See ordering data for SIMATIC NET upgrade packages

3) SIMATIC NET Version V12 SP2 is supplied together with WinCC V7.4 SP1

4) SOFTNET-S7 Lean included in scope of supply of WinCC V7.4 SP1

PG/PC communication components for SIMATIC (for WinCC V7.5)

PROFIBUS SIMATIC S5 PROFIBUS FDL SIMATIC S7
Protocol Suite
PROFIBUS DP PROFIBUS FMS Article No.
WinCC – channel DLL
SIMATIC S5 PROFIBUS FDL
Channel DLL for S5-FDL
Included in the basic package
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions
Included in the basic package
PROFIBUS DP
Channel DLL for PROFIBUS DP
Included in the basic package
Communication components for extension of the OS/OP
CP 5612 2)
PCI card (32-bit) for connecting a PG/PC to PROFIBUS (communication software included in WinCC basic package)
6GK1561-2AA00
CP 5622 2)
PCI Express X1 card (32-bit) for connecting a PG/PC to PROFIBUS (communication software included in WinCC basic package)
6GK1562-2AA00
CP 5711
USB adapter for connecting a PG/PC to PROFIBUS or MPI (communication software included in WinCC basic package)
6GK1571-1AA00
CP 5613 A3
PCI card (32-bit) for connecting a PC to PROFIBUS (S7-5613, DP-5613 or FMS-5613 communication software required)
6GK1561-3AA02
CP 5614 A3
PCI card (32-bit) for connecting a PC to PROFIBUS (communication software must be ordered separately)
6GK1561-4AA02
CP 5623
PCI Express X1 card (32-bit) for connecting a PG/PC to PROFIBUS or MPI (HARDNET PB S7 or HARDNET PB DP communication software required)
6GK1562-3AA00
HARDNET PB S7Communication software for S7 functions + FDL 6GK1713-5CB15-0AA0
HARDNET PB DPCommunication software for DP master + FDL 6GK1713-5DB15-0AA0

• System interface possible

1) See ordering data for SIMATIC NET upgrade package

2) SIMATIC NET Version 8.2 SP1 is supplied together with WinCC V7.4 SP1

Communication components for PG/PC for SIMATIC (for WinCC V7.4 SP1)

PROFIBUS SIMATIC S5 PROFIBUS FDL SIMATIC S7
Protocol Suite
PROFIBUS DP PROFIBUS FMS Article No.
WinCC – channel DLL
SIMATIC S5 PROFIBUS FDL
Channel DLL for S5-FDL
Included in the basic package
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions
Included in the basic package
PROFIBUS DP
Channel DLL for PROFIBUS DP
Included in the basic package
Communication components for extension of the OS/OP
CP 5612 2)
PCI card (32-bit) for connecting a PG/PC to PROFIBUS (communication software included in WinCC basic package)
6GK1561-2AA00
CP 5622 2)
PCI Express X1 card (32-bit) for connecting a PG/PC to PROFIBUS (communication software included in WinCC basic package)
6GK1562-2AA00
CP 5711
USB adapter for connecting a PG/PC to PROFIBUS or MPI (communication software included in WinCC basic package)
6GK1571-1AA00
CP 5613 A3
PCI card (32-bit) for connecting a PC to PROFIBUS (S7-5613, DP-5613 or FMS-5613 communication software required)
6GK1561-3AA02
CP 5614 A3
PCI card (32-bit) for connecting a PC to PROFIBUS (communication software must be ordered separately)
6GK1561-4AA02
CP 5623
PCI Express X1 card (32-bit) for connecting a PG/PC to PROFIBUS or MPI (HARDNET PB S7or HARDNET PB DP communication software required)
6GK1562-3AA00
HARDNET PB S7Communication software for S7 functions + FDL 6GK1713-5CB08-2AA0
Version 8.2 SP1 1)2)
For Windows 7 (32/64-bit) and Server 2008 R2 (64-bit)
HARDNET PB DPCommunication software for DP master + FDL 6GK1713-5DB08-2AA0
Version 8.2. SP11)2)For Windows 7 (32/64-bit) and Server 2008 R2 (64-bit)

• System interface possible

1) See ordering data for SIMATIC NET upgrade package

2) SIMATIC NET Version 8.2 SP1 is supplied together with WinCC V7.4 SP1

Communication examples

WinCC single-user system: PROFIBUS with S7 communication

WinCC single-user system: Industrial Ethernet with S7 communication

WinCC: Multi-user system with operable server

OPC link

Technical specifications

Type SIMATIC WinCC V7.5
PC hardware requirements
Processor type
Minimum Single-user station/server: Dual-core; 2.5 GHz
Client: Dual-core; 2.5 GHz
Recommended Single-user station/server: Multi-core; 3.5 GHz
Client: Multi-core; 3 GHz 2)
Work memory RAM
Minimum Windows 10 (64-bit)Single-user station/server: 4 GBClient: 2 GB
Windows Server 2012 R2/ Windows Server 2016Server: 4 GB
Recommended Windows 10 (64-bit)Single-user station/server: 4 GBClient: 4 GB
Windows Server 2012 R2/ Windows Server 2016Server: 8 GB
Graphics resolution
Minimum 800 x 600
Recommended 1 920 x 1 080
Hard disk
Minimum Single-user station/server: 80 GB
Client: 20 GB
WebClient/DataMonitor Client: 5 GB
Recommended Single-user station/server: 160 GB
Client: 40 GB
WebClient/DataMonitor Client: 10 GB
DVD-ROM/USB interface For software installation and license transfer

Type SIMATIC WinCC V7.5
Functionality/quantity structure
Number of messages 150 000
Message text (number of characters) 10 x 256
Message archive System-limited 1)
Process values per message 10
Constant load of messages, max. Server/single-user station: 10/s
Message burst, max. Server/single-user station: 2 000/10 s every 5 min
Archive
Archive data points Max. 80 000 per server 2)
Archive types Short-term archive with and without long-term archiving
Data storage format Microsoft SQL Server 2016 SP2
Measured values per second Server/single-user station: up to 30 000/s 4)
User archive
Total archives No limit
Fields per user archive 500 (maximum number of 1 000 000 fields)
Data records per user archive 10 000
User archive views No limit
Graphics system
Number of screens System-limited 1)
Number of objects per screen System-limited 1)
Number of controllable fields per screen System-limited 1)
PowerTags 256 K 3)
Trends
Trend views per image 25
Trends per trend view 80
User administration
User groups 128
Number of users 128
Authorization groups 999
Configuration languages 5 European (en, de, fr, it, es),
4 Asian (zh-CN, zh-TW, ko, ja)
Protocols
Message sequence reports
(simultaneously)
1 per server/single-user station
Message archive reports
(simultaneously)
3
User reports System-limited 1)
Report lines per group 66
Tags per report 300 5)
Multi-user system
Server 18
Uni Client (without its own project) Max. 64
Multi-Client (with its own project) Max. 50

1) Dependent on available storage space

2) Dependent on number of licensed archive tags (ArchiveTags)

3) Dependent on the number of licensed PowerTags

4) Dependent on system performance, especially of hard disk (SSD/RAID recommended)

5) Number of variables per report depends on process communication performance

TIA Portal PLC programming
TIA Portal PLC programming
STEP 7 (PLC Classic Software)
STEP 7 (PLC Classic Software)
WinCC (TIA) V19 -HMI & SCADA
WinCC (TIA) V19 -HMI & SCADA
WinCC (TIA) Runtime Adv. V19
WinCC (TIA) Runtime Adv. V19
WinCC (TIA) Runtime Pro. V19
WinCC (TIA) Runtime Pro. V19
SIMATIC WinCC Unified
SIMATIC WinCC Unified
WinCC V8.0 (SCADA)
WinCC V8.0 (SCADA)
Startdrive (TIA) V19
Startdrive (TIA) V19

Did you know, we are an entrusted Siemens approved partner?

Loading...