Safe bar code positioning system
The world's first safety bar code positioning system, FBPS 600i, requires just one sensor for safe position detection. The device is connected to a safe evaluation unit via two SSI interfaces or to a safety controller via PROFIsafe and is suitable for applications up to Performance Level e. This allows easy implementation of safety functions and a reduction in space and installation requirements.

FBPS 600i – Safe Bar Code Positioning System up to PL e
Expanded Interface Options for Greater Flexibility
The FBPS 600i series offers safe position detection with just one sensor, streamlining integration and setup. With the addition of a PROFIsafe interface, the system now opens up new possibilities for flexible and efficient safety applications.
Two Versatile Models to Suit Your Needs:
FBPS 648i
Connects directly to a safety PLC via PROFIsafe. Thanks to its integrated switch, a linear topology can be easily configured. It also features a non-safe SSI interface for direct connection to a drive’s frequency inverter (FI). Configuration is simple via the hardware manager using GSDML or FI settings.FBPS 6x7i
Interfaces via two SSI connections to a safe evaluation unit, such as a frequency inverter or safety controller.
Both models support applications requiring safe positioning up to Performance Level e (PL e), enabling straightforward implementation of safety functions while reducing installation and maintenance costs.
Features and benefits
- Safe positioning with just one device up to Performance Level e (PL e).
- Direct connection to safe frequency inverters or safety controls (F-PLC).
- Compact design with low space requirements and simplified installation.
- Particularly straightforward safety function implementation.
- Short braking distances and optimised speeds thanks to a fast error response of just 10 ms – ideal for use on fast stacker cranes and electric monorail systems.
- Reliable operation thanks to simultaneous scanning of multiple codes as well as extremely robust, UV-resistant bar code tape.
- Large working range from 50 mm to 170 mm for a wide range of applications with curves.
- Sophisticated mounting system for easy installation and seamless integration.
The new FBPS 648i model rounds out the portfolio of positioning sensors with PROFIsafe and the combined SSI interface.
Technical Features
FBPS 600i

Safety | Safety PL e, SIL 3, category 4 (EN ISO 13849-1 and IEC 61508) | |
Error response time | 10 ms … 400 ms (adjustable) | |
Connection | 2x SSI interface: 2x M12 connector PROFINET/ PROFIsafe, opt. SSI: 2(3)x M12 connector Power supply: M12 connector Configuration and diagnosis: Mini USB | |
Reproducibility | +/- 0.15 mm (1 sigma) | |
Reading distance | 50 … 170 mm | |
Protection class | IP 65 | |
Temperature range | -5 … +60°C With heating: -35…+60°C | |
Dimensions, W x H x D | Connections on the side: 116.3 x 112.5 x 51.5 mm Bottom connections: 105 x 123.8 x 51.5 mm | |
Display (optional) | Display of position and status information | |
Status signal of reading quality | For early detection of soiling |
Bar code tape

Features | Extremely robust plastic tape, UV- resistant, self-adhesive with acrylic adhesive, position values printed in plain text | |
Standard bar code tapes | Height: 25 mm, 47 mm Length: up to 200 m | |
Configurable bar code tapes | Height: 20 mm to 140 mm Selectable start and end value ranging from 0 to 10,000 m Twin tape | |
Bar code grid dimension | 30 mm / 40 mm |